Abstract: We designed a formaldehyde gas detection sensor based on the aldehyde oxidase principle. Its sensitive component was manufactured through such process as selfassembly, activation, and adsorption with gold electrode as substrate, and had better electrocatalysis and oxidation effect to formaldehyde. We further designed a formaldehyde gas detection biosensor with the electrode and a LPC1788 chip as its CPU. The biosensor was tested with formaldehyde gas of 0.1 mg/m3.Results demonstrate that the sensor has as rapid response time as 20 s, shorter recovery time and lower detection limit as 0.01 mg/m3 to formaldehyde gas.