J4 ›› 2014, Vol. 27 ›› Issue (3): 57-60.doi: 10.3976/j.issn.1002-4026.2014.03.011

• Article • Previous Articles     Next Articles

Material investigation of hydrogen chloride catalytic oxidation reactor

 LI Xiao-Ming, LIANG Rui-Yuan, QI Guo-Dong, WANG Ping, BIAN Xiang-Cheng, CHEN Qi-Bao, HAN Sheng-Bing, ZHAO Gui-Rong   

  1. Gansu Yinguangjuyin Chemical Co. Ltd., Baiyin 730900, China
  • Received:2013-10-15 Online:2014-06-20 Published:2014-06-20

Abstract:

        We measure the corrosion rate of such representative metal materials as Hastelloy C-2000, Hastelloy C-4, Inconel 600, Incoloy 825, 316 L, Ni-6 and pure Ta. We determine corrosion resistance rates of different metal materials in hydrogen chloride catalytic oxidation reactor based on weight loss rate and thickness variety rate of hanging sheets between pre and postexperiments and their corrosion rates. Experiments indicate that pure Ta has the best corrosion resistance rate of 0.309 3 g / (dm2·Month) and 0.053 0 mm / a.Inconel 600 has the second best corrosion resistance rate of 0.566 8 g / (dm2·Month) and 0.230 2 mm / a.

CLC Number: 

  • TQ052