Abstract:

          We reduce the blind ends of steel tubes in eddy current fault detection by the automatic control over the gain of a preamplifier and performance improvement of a bandpass filter for the characteristic of strong signal generated at the end of a steel tube. We can detect the steel pit at the 103 mm away from one end of a steel tube of diameter 168 mm and thickness 6 mm.

Key words: blind end, through type coil round, eddy current fault detection

CLC Number: 

  • TG115

Open Access This article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0), which permits third parties to freely share (i.e., copy and redistribute the material in any medium or format) and adapt (i.e., remix, transform, or build upon the material) the articles published in this journal, provided that appropriate credit is given, a link to the license is provided, and any changes made are indicated. The material may not be used for commercial purposes. For details of the CC BY-NC 4.0 license, please visit: https://creativecommons.org/licenses/by-nc/4.0