山东科学 ›› 2018, Vol. 31 ›› Issue (4): 26-30.doi: 10.3976/j.issn.1002-4026.2018.04.005

• 中药与天然活性产物 • 上一篇    下一篇

氢核磁定量分析技术测定人参皂苷Rd对照品含量的研究

闫慧娇,王志伟,林云良,高红梅,李锋,王晓,耿岩玲*   

  1. 齐鲁工业大学(山东省科学院),山东省分析测试中心,山东省科学院中药过程控制研究中心,山东 济南 250014
  • 收稿日期:2017-08-18 出版日期:2018-08-20 发布日期:2018-08-20
  • 通信作者: 耿岩玲(1973—),女,副研究员,研究方向为中药与复方活性成分及标准样品研制。
  • 作者简介:闫慧娇(1984—)女,助理研究员,研究方向为天然产物提取分离及高值化利用。
  • 基金资助:

    国家重点研发计划(2016YFF0201806-5)

Quantitative 1H NMR based content determination of ginsenoside Rd

YAN Hui-jiao, WANG Zhi-wei,LIN Yun-liang, GAO Hong-mei, LI Feng, WANG Xiao, GENG Yan-ling*   

  1. Process Control Center for Traditional Chinese Medicine, Shandong Analysis and Test Center,Qilu University of Technology(Shandong Academy of Sciences), Jinan 250014,China
  • Received:2017-08-18 Online:2018-08-20 Published:2018-08-20

摘要:

建立了氢核磁定量技术准确、快速测定人参皂苷Rd对照品含量的方法。考察了核磁共振实验条件对测定结果的影响。选择混合溶剂氘代DMSOd6∶D2O(9∶1,V/V)为溶剂,苯甲酸为内标,观测频率400.13 MHz,脉冲延迟时间5 s,采样次数32 次,采集人参皂苷Rd和苯甲酸内标混合物的1H NMR谱图。定量峰为苯甲酸2位和6位质子信号δ 7.94,人参皂苷Rd 24位质子信号δ 5.07。结果表明,氢核磁定量测定的线性相关系数R = 0.997 8,精密度相对标准偏差为0.65%,回收率分别为98.69%~102.54%,相对标准偏差为1.92%,说明该方法准确性良好。实际测定3 批人参皂苷Rd的质量分数分别为98.87%,98.79%和98.92%。氢核磁定量技术测得对照品的质量分数略低于HPLC的面积归一化法。该方法无需待测物对照品,且对检测样品无破坏性、重现性好,可用于人参皂苷Rd对照品的含量测定和质量控制。

关键词: 氢核磁定量, 人参皂苷Rd, 含量测定

Abstract:

To establish an accurate and rapid method for content determination of ginsenoside Rd with quantitative 1H NMR. Benzoic acid served as internal standard, DMSO-d6 and D2O (9:1, V/V) as solution.1H NMR spectra of the mixture of ginsenoside Rd and benzoic acid were acquired with spectrometer frequency 400.13 MHz scanning 32 times, relaxation delay time 4 s. Ginsenoside Rd proton peak at δ 5.07 and benzoic acid signal δ 7.94 served as quantification peaks. Linear regression equation of correlation coefficient of 0.997 8, RSD of precision were less than 0.65%, the average recoveries were in the range of 98.69% to 102.54% with RSD less than 1.92%. The contents of 3 batches of ginsenoside Rd were 98.87%, 98.79% and 98.92%. Experimental results show that the concentration of quantitative 1H NMR determined ginsenoside Rd is slightly lower than that by HPLC without reference substance. The method is simple, accurate, and has good application value, can be used for the content determination and quality control of ginsenoside Rd.

Key words: content determination, quantitative 1H NMR, ginsenoside Rd

中图分类号: 

  • R284.1

开放获取 本文遵循知识共享-署名-非商业性4.0国际许可协议(CC BY-NC 4.0),允许第三方对本刊发表的论文自由共享(即在任何媒介以任何形式复制、发行原文)、演绎(即修改、转换或以原文为基础进行创作),必须给出适当的署名,提供指向本文许可协议的链接,同时表明是否对原文作了修改,不得将本文用于商业目的。CC BY-NC 4.0许可协议详情请访问 https://creativecommons.org/licenses/by-nc/4.0